Pretraining Transformers with Quantized Softmax in Attention

  • 2026-11-20 08:10:21
  • Shangzhen Zhu, Muyan Hu, Tomasz Kozlowski
  • 0

Abstract

Low-precision Transformer systems increasingly quantize attention matrix multiplications, while softmax often remains at higher precision. During pretraining, an approximate softmax changes the gradients that train the model as well as its forward computation. We study this interaction with K-interval attention, which approximates the exponential using K+1 grid values. We vary per-row grid calibration, interpolation versus hard rounding, and the placement of a straight-through surrogate relative to normalization. We derive the corresponding backward rules, including calibration derivatives, and compare these choices in pretraining experiments matched on model, data, and optimizer. Detaching the row extrema leaves the forward computation unchanged but produces a delayed increase in validation loss, under both min-max and fixed-window calibration. With hard rounding at K=4, min-max calibration and a pre-normalization surrogate incur a large loss gap; changing either choice substantially reduces it. At 124M parameters and 2.5B training tokens, fixed-window calibration with interpolation ends +0.007 nats from softmax at K=4; with hard rounding it ends +0.019 nats at K=4 under a post-normalization surrogate and +0.004 nats at K=16 under a pre-normalization surrogate.

 

Quick Read (beta)

loading the full paper ...